ABOUT US
Focuses on the management and operation of industrial volatile organic waste gas, and is committed to providing customers with full life cycle system solutions with high purification efficiency and low operational energy consumption.

Under the action of catalyst, ammonia is sprayed into the flue gas at the appropriate temperature (280℃~420℃), and ammonia reacts chemically with NOx in the flue gas, reducing NOx to N₂ and H₂O, which is to the purpose of denitrification.
Exhaust air volume: 500~50,000Nm³/h
Reaction temperature: 280~400℃
Emission standard: NOx: <50mg/Nm³ NH₃: <3mg/Nm³ (Ammonia escape)
Heating energy: Gas and electricity